RM SW V41c02 Final - Version History: ************************************* Changes V41c02 Final vs. V41b01 Final: *************************************** -) RM now supports the extended Status message format of the new Dimming actuator. The following output states are supported: ON, Off, ON-locked, Off-locked, Blinking, Off-Overtemperature, Off-Overload - they are displayed as a combination of Status-text and Symbol. Due to limitation in the RM display only the output status of the extended status message is displayed. Changes V41b01 Final vs. V41a03 Final: *************************************** -) Updated the internal RF-library with the latest optimizations -) Optimized the Touch Sensor operation Bugfixes/Changes V41a03 Final vs. V40a Final: ********************************************** -) The Room-Manager will no longer send out different time triggered events that will be activated at the same time immediately but add a short delay time of several seconds between these elements (Shadings, Room heating acutators, Timers,...) -) Reduced the cyclic sending time of the Room 1 Set temperature to 30 minutes (from 6 hours) when the channel is connected to other devices (for example SHC) -) RM now supports the extended Status message format of the new actuator generation. The following output states are supported: ON, Off, ON-locked, Off-locked, Blinking, Off-Overtemperature - they are displayed as a combination of Status-text and Symbol. Due to limitation in the RM display only the output status of the extended status message is displayed. -) Output 1-10 of the Room-Manager will now always send out a RF-command to connected devices independent if the output already has the desired status (Mainly a change for Logic functions and Scenes to be able to always send out the desired output status if a change occurs). -) The battery state page will now also display and track the battery state of the following inputs: Room 1 external temperature sensor, Operation type input, Heating valves of a room (sum of all valves per room -> if one has low battery the state is set to low) -) Improved the detection of Touch sensor operations and RF-events to ensure a smoother and more reliable operation. -) Corrected some display issues with the Bluetooth Room-Manager Bugfixes/Changes V40a Final vs. V39b BB04 Final: ************************************************ -) RM will no longer send the 3rd repeat of a HRV-IN message to everyone to prevent learning an alternative path -) Added a new Binary output channel for the Operation type (Heating/cooling) that can be connected to other devices. -) Added a new Binary Input channel that can be used to change the operation type (Heating, Cooling) for all rooms (needed for connections with Multi-heating actuators) -) Implemented the Cooling function for Connections with Multi-heating actuators. A Multi-Heating actuator input can either be used as Heating-, Cooling- and Heating/Cooling-Request in combination with the RM. -) Rooms with RF Radiator Valves will now send a Setpoint of 0°C if the RM is set to operation type cooling. -) The Room-manager will no longer restart occasionally if it needs to send a lot of RF commands while under heavy operation of the sensor wheel -) The text "operation modi" has been changed to "operation type" in the english language version -) The Room inertance will no longer trigger false Setpoint changes before a time range that is invalid. Bugfixes/Changes V39b BB04 Final vs. V39a BB06 Final: ***************************************************** -) Added support for the new Sensor Hardware V15. This version can work with both sensor hardware solutions! -) Fixed a bug that affected Marker 2-4 in combination with the Energy-ranges that caused logic operations to not work correctly -) Removed the blank space in the ON/OFF text in CZ language to prevent bad display when changing the heating state of a room -) Bugfix: Heating Sum state of a room will now only be ON if at least 1 HRV has a valve state >0% -) Bugfix: Heating Sum state of all rooms will now correctly be calculated for all different room types. -) Bugfix: Fixed connection problems between Bluetooth chip and RM that could cause connection interruption when using the coniugo BT modem or sending long SMS -) Bugfix: External inputs will now correctly activate/deactivate the safety function -) Change: If a MCH is conected the RM will now always send both RF commands if either set- or actual temperature changes -) Bugfix: Activating/deactivating the safety function will now work properly if activating different zones -) Bugfix: The indices for window contacts of the different rooms will now be initialized correctly -) Bugfix: The presence simulation that has been activated by a safety alarm will now be deactivated correctly when the arlarm ends.